STEELL ENCAPSULATED CALCIUM SULPHATE CORE

“GWI” PANEL – Technical sheet

Galvanised steel encapsulated panel with vertical and re-entrant structural reinforcement along the whole perimeter comprising two steel trays doubled along the edges and clinched together. Micro area for perimeter dilations. Calcium sulphate core.

Brevetto Europeo N. 1409812.
Patent pending: Cina, Giappone, Sud Corea.

Norme di riferimento: EN 12825; PSA/MOB;

Structural Features

Physical Features

Terms and definitions according to EN 12825

• Safety factor: the factor by which the ultimate load is divided to establish the working load.
• Ultimate load: maximum load at the time of failure of the element during the specified ultimate load test procedure.
• Working load: load given by dividing the ultimate load by the safety factor.
• Distributed load: is an indicative value not defined by EN 12825. It is given by multiplying five times the concentrated load.

Coverings

• Janus loose-lay magnetic tiles
• Stainless steel or Aluzinc encapsulation
• Factory bonded coverings: ceramic/marble/granite, pvc/rubber/linoleum, multi-layer wood.

Understructure

• Match with ST1, ST2, ST3, ST1G, ST2G, ST3G.